ULTIMATE

U Protect Pipe Section Alu2

U Protect Alu-Faced pipe sections for HVAC, Marine or Industry applications
Read more
Read less

Description

U Protect pipe solutions provides an easy to install and lightweight efficient solution for thermal and acoustic insulation and fire resistance in HVAC pipe systems, using ULTIMATE mineral wool. ISOVER U Protect pipes provides topclass thermal insulation for hot water and heating pipes and secures the building fire safety for penetrations up to EI 120 according to EN 1366-3. Alufacing provides efficient water vapour barrier when intact and seems carefully taped.

U Protect pipe sections are manufactured from inorganic chemically biosoluble materials and do not include anything that would have effect on corrosion and shall not facilitate microbial growth.

Key Benefits

  • Sound absorption
  • Fire resistance
  • Reduced carbon footprint
  • Fast installation

Technical Characteristics

Symbol Unit Quantities and declared values Standard
Reaction to fire Symbol- Unit- Quantities and declared valuesNon-combustible, Euroclass A2L-s1,d0 StandardEN 13501-1
Water behaviour Quantities and declared valuesHydrophobic StandardEN 12086
Chemical behaviour Quantities and declared valuesSilicone-free, Sulphide-free StandardAGI Q 132
Application field Quantities and declared valuesISOVER U Protect pipes provides topclass thermal insuLation for hot water and heating pipes and secures the building fire safety for penetrations up to EI 120 according to EN 1366-3 Alufacing provides efficient water vapour barrier when intact and seems carefully taped StandardEN 1366-3
CE marking Quantities and declared valuesMW-EN14303-T8-ST(+)620-MV2-CL10 MW-EN14303-T9-ST(+)620-MV2-CL10 StandardEN 14303
Quality management Quantities and declared valuesISOVER is certified according to EN ISO 9001 and EN ISO 14001 StandardEN ISO 9001 EN ISO 14001

Thermal Conductivity

Characteristic Symbol Unit Quantities and declared values Standard
CharacteristicThermal conductivity SymbolT Unit[°C] Quantities and declared values10 Quantities and declared values_50 Quantities and declared values__100 Quantities and declared values___150 Quantities and declared values____200 Quantities and declared values_____300 Quantities and declared values______- StandardEN ISO 13787
EN ISO 849
CharacteristicThermal behaviour Symbolλ Unit[W/(m•K)] Quantities and declared values0.032 Quantities and declared values_0.037 Quantities and declared values__0.043 Quantities and declared values___0.052 Quantities and declared values____0.062 Quantities and declared values_____0.092
CharacteristicThermal conductivity SymbolT Unit[°C] Quantities and declared values< 620 °C (tape and alu-facing 80 °C) StandardEN 14707
CharacteristicMelting point Symbol- Quantities and declared values> 1,000 °C

Standard Dimensions

Thickness
d [mm]
Length [mm] Diameter Ø [mm]
15 18 22 28 35 42 48 54 57 60 64 70 76 89 102 108 114 133 140 159 168 219 273
Thickness
d [mm]
25
Length [mm]1,200 15• 18• 22• 28• 35• 42• 48• 54• 57• 60• 64• 70• 76• 89• 102 108• 114• 133 140 159 168 219 273
Thickness
d [mm]
30
Length [mm]1,200 15• 18• 22• 28• 35• 42• 48• 54• 57• 60• 64• 70• 76• 89• 102• 108• 114• 133• 140• 159• 168• 219• 273•
Thickness
d [mm]
40
Length [mm]1,200 15• 18• 22• 28• 35• 42• 48• 54• 57• 60• 64• 70• 76• 89• 102• 108• 114• 133• 140• 159• 168• 219• 273•
Thickness
d [mm]
50
Length [mm]1,200 15• 18• 22• 28• 35• 42• 48• 54• 57• 60• 64• 70• 76• 89• 102• 108• 114• 133• 140• 159• 168• 219• 273•
Thickness
d [mm]
60
Length [mm]1,200 15 18 22 28• 35• 42• 48• 54• 57• 60• 64• 70• 76• 89• 102• 108• 114• 133• 140• 159• 168• 219• 273•
Thickness
d [mm]
70
Length [mm]1,200 15 18 22 28 35• 42• 48 54 57 60• 64 70• 76• 89• 102• 108• 114• 133• 140• 159• 168• 219• 273•
Thickness
d [mm]
80
Length [mm]1,200 15 18 22 28 35 42• 48• 54• 57• 60• 64• 70 76• 89• 102• 108• 114• 133• 140• 159• 168• 219• 273•
Thickness
d [mm]
100
Length [mm]1,200 15 18 22 28 35 42 48 54 57 60 64 70 76• 89• 102• 108• 114• 133• 140• 159• 168• 219• 273•
Thickness
d [mm]
120
Length [mm]1,200 15 18 22 28 35 42 48 54 57 60 64 70 76• 89 102 108 114• 133 140• 159• 168• 219• 273•
Notes
Pipe Sections are alu-faced, slit open from one side and equipped with tape closure – further information on demand.
* Check availability and delivery details from your local ISOVER supplier.

Documents

U Protect Pipe Section Alu2
TDS_U_Protect_Pipe_Section_Alu2.pdf
U Protect Pipe Section Alu2
ISOVER_BROCHURE_HVAC_CE_International.pdf
U Protect Pipe Section Alu2
ISOVER_Brochure_ULTIMATE-Light-stone-wool
U Protect Pipe Section Alu2
ISOVER_BROCHURE_U_Protect_Pipe_Section.pdf
U Protect Pipe Section Alu2
SGTI_Brochure_HVAC_Label_Contributions_FINAL.pdf
U Protect Pipe Section Alu2
SGTI_Brochure_HVAC_Saint-Gobain-Technical-Insulation.pdf
U Protect Pipe Section Alu2
Classification_report_for_combustible_pipes.pdf
U Protect Pipe Section Alu2
Classification_report_for_non-combustible_pipes.pdf
U Protect Pipe Section Alu2
DOP_Pipe-Sections_ISOVER.pdf
U Protect Pipe Section Alu2
EPD_Ultimate.pdf
U Protect Pipe Section Alu2
EUCEB_Certificate_CLIMAVER.pdf
U Protect Pipe Section Alu2
M1_Classification.pdf
U Protect Pipe Section Alu2
SUIS_Ultimate.pdf