Description
Design specifications for storage tanks containing cryogenic fluids such as liquefied natural gas (LNG), ethylene or nitrogen for chemical or combustion processes are highly demanding, both in terms of construction and insulation. With tank volumes expanding and contracting depending on liquid levels, the insulation must offer high compressibility and resilience.
To meet this requirement,
ISOVER has developed the unique CRYOLENE product range. CRYOLENE 682, available
in rolls up to 40 m long for faster installation with fewer joints, has been
designed for the insulation of cryogenic tank walls. The properties and
performance of CRYOLENE 682 have been extensively tested by external institutes
and the products are well-proven through decades of successful use worldwide in
chemical and LNG applications.
Key Benefits
- High flexibility
- Improved logistics
- Fast installation
- Sound absorption
- Lightweight
Technical Characteristics
| Symbol | Unit | Quantities and declared values | Standard | |
|---|---|---|---|---|
| Specific thermal capacity | Symbolc | UnitkJ/(kg·K) | Quantities and declared values1.03 | StandardISO 10456 |
| Reaction to fire | Symbol- | Unit- | Quantities and declared values 682 VV : Euroclass A1 Non combustible; 682 AA : Euroclass A2-s1, d0 682 VV : Fire Spread Index < 0; Smoke Development Index < 0 682 AA : Fire Spread Index < 35; Smoke Development Index < 0 | StandardEN 13501-1 ASTM E84 |
| Water behaviour | SymbolWS | Unitkg/m² | Quantities and declared valuesNo short term water absorption by partial immersion (WS1 ≤ 1 kg/m2) | StandardEN ISO 29767 |
| Chemical behaviour | Symbol- | Unit- | Quantities and declared valuesDo not contribute to corrosion of stainless steel | StandardASTM C795/871 |
| Application field | Quantities and declared valuesProduct for the storage of refrigerated and liquefied gases such as Liquid Natural Gas storage tanks | StandardEN 14620-4 | ||
| Material | Quantities and declared valuesCRYOLENE products are highly resilient glass mineral wool rolls designed to retain their fibers elasticity over time at temperatures ranging from -170 °C to +120 °C With quality marks EUCEB and RAL by the Gütegemeinschaft Mineralwolle e. V., unrisky regarding health according to German decree on dangerous substances, decree on prohibition of chemicals and to regulation EC No 1272/2008 Note Q | StandardCINI 2.1.02 | ||
| Facing | Quantities and declared values682 VV: with a reinforced glass veil facing 682 AA: with a reinforced aluminium veil facing | Standard- | ||
| Miscellaneous | Quantities and declared values Designation code : MW-EN 14303-T3-WS1 | StandardEN 14303 | ||
| Quality management | Quantities and declared valuesCE-marked according to EN 14303 ISOVER is certified according to EN ISO 9001 and EN ISO 14001 | StandardEN 14303 EN ISO 9001 EN ISO 14001 | ||
| Delivery form | Quantities and declared valuesPlease contact your local ISOVER dealer All dimensions require minimum order quantities | Standard- |
Thermal Conductivity
| Characteristic | Symbol | Unit | Quantities and declared values | Standard | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CharacteristicThermal conductivity | SymbolT | Unit[°C] | Quantities and declared values-150 | Quantities and declared values_-120 | Quantities and declared values__-100 | Quantities and declared values___-50 | Quantities and declared values____- | Quantities and declared values_____10 | Quantities and declared values______- | StandardEN 12667 EN ISO 13787 |
||
| Symbolλ | Unit[W/(m•K)] | Quantities and declared values0.013 | Quantities and declared values_0.017 | Quantities and declared values__0.019 | Quantities and declared values___0.026 | Quantities and declared values____0.034 | Quantities and declared values_____0.036 | |||||
| CharacteristicThermal behaviour | SymbolT | Unit[°C] | Quantities and declared valuesOperating temperature range -170 °C until + 120 °C | |||||||||