Description
ULTIMATE mineral wool provides aunique high-performance profile : It combines safety, comfort andease of handling.
Key Benefits
- Fire resistance
- Lightweight
- Sound absorption
- Thermal insulation
Technical Characteristics
Symbol | Unit | Quantities and declared values | Standard | |
---|---|---|---|---|
Specific thermal capacity | Symbolc | UnitkJ/(kg·K) | Quantities and declared values1.00 | StandardISO 10456 |
Reaction to fire | Symbol- | Unit- | Quantities and declared valuesMelting point according to DIN 4102, part 17: ¨ 1000 °C. Non combustible according to IMO-Resolution MSC.61(67)-(FTP- Code), IMO MSC/Circ. 1120. Surface materials with low flame-spread characteristics. Homologated for shipbuilding | StandardRESOLUTION MSC.307(88) (2010 FTP CODE) |
Application field | Quantities and declared values Thermal insulation, acoustic insulation and fire protection constructions in shipbuilding. Approved for A-Class steel constructions | Standard- | ||
Material | Quantities and declared valuesMineral wool with quality mark RAL by the Gütegemeinschaft Mineralwollee . V., unrisky regarding health according to German decree on dangerous substances, decree on prohibition of chemicals and to guideline EU97/69 Nota Q. | |||
Facing | Quantities and declared valuesOne-sided faced with glass fiber cloth with a gram weight of 220 g/m2 | |||
Water vapour diffusion resistance factor | Symbolμ | Quantities and declared values~ 1.0 | ||
Thermal coefficient of expansion | Symbolα | Unit1/K | Quantities and declared valuesNo change in dimensions within the application field. | |
Quality management | Symbol- | Unit- | Quantities and declared valuesISOVER is certified according to DIN EN ISO 9001 and DIN EN ISO 14001 | StandardEN ISO 9001 EN ISO 14001 |
Thermal Conductivity
Characteristic | Symbol | Unit | Quantities and declared values | Standard | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CharacteristicThermal conductivity | SymbolT | Unit[°C] | Quantities and declared values10 | Quantities and declared values_50 | Quantities and declared values__100 | Quantities and declared values___150 | Quantities and declared values____200 | Quantities and declared values_____300 | Quantities and declared values______400 | Quantities and declared values_______- | StandardEN 14706 | |
SymbolλN,R | Unit[W/(m•K)] | Quantities and declared values0.031 | Quantities and declared values_0.036 | Quantities and declared values__0,042 | Quantities and declared values___0,050 | Quantities and declared values____0,059 | Quantities and declared values_____0,080 | Quantities and declared values______0,109 | ||||
CharacteristicThermal behaviour | SymbolT | Unit[°C] | Quantities and declared values≤ 650 by pure thermal stress (U SeaProtect Slab 40 – 90) The thickness of the insulating layer has to be correctly dimensioned so that the faced side is exposed to a maximum of 100 °C. From 150 °C on the binder starts to volatilise. |
Air Flow Resistivity
Characteristic | Symbol | Unit | Quantities and declared values | Values | Standard |
---|---|---|---|---|---|
CharacteristicAir flow resistivity | Symbolσ | Unit[KPa• s/m2] | Quantities and declared valuesDensity 50 kg/m3 | Values[40-60] | StandardDIN EN 29053 |
Standard Dimensions
Thickness d [mm] | Length [mm] | Width b [mm] |
---|---|---|
Thickness d [mm]25 | Length [mm]1200 | Width b [mm]625 |
Thickness d [mm]30 | Length [mm]1200 | Width b [mm]625 |
Thickness d [mm]50 | Length [mm]1200 | Width b [mm]625 |
Thickness d [mm]60 | Length [mm]1200 | Width b [mm]625 |
Notes
* On some products, minimum order quantities are requested.
** Further dimensions on request.