ULTIMATE

U SeaProtect Roll 56

Rolls unfaced – Density 56 kg/m³
Read more
Read less

Description

ULTIMATE mineral wool provides a unique high-performance profile:
It combines safety, comfort and ease of handling.

Key Benefits

  • Fire resistance
  • Sound absorption
  • Recycled glass
  • Lightweight

Technical Characteristics

Symbol Unit Quantities and declared values Standard
Specific thermal capacity Symbolc UnitkJ/(kg.K) Quantities and declared values1.03 StandardISO 10456
Reaction to fire Symbol- Unit- Quantities and declared valuesMelting point according to DIN 4102, part 17: ≥ 1000 °C Non combustible according to IMO-Resolution Holologated for shipbuilding according to EC Type Examination Certificates Nr.: MED-B+D Certificate = visit our website StandardDIN 4102-17 IMO-Resolution MSC.307(88)-(FTP-Code 2010)
Chemical behaviour Quantities and declared valuesSulphide free Standard-
Application field Quantities and declared valuesThermal insulation, acoustic insulation and fire protection constructions in shipbuilding
Material Quantities and declared valuesMineral wool with quality mark RAL by the Gütegemeischaft Mineralwolle e.V., unrisky regarding health according to German decree on dangerous substances, decree on prohibition of chemicals and to Regulation (EC) N°1272/2008
Water vapour diffusion resistance factor Symbolμ Quantities and declared values~ 1 StandardISO 10456
Quality management Symbol- Quantities and declared valuesISOVER is certified according to DIN EN ISO 9001 and DIN EN ISO 14001 StandardEN ISO 9001 EN ISO 14001 EN ISO 50001

Thermal Conductivity

Characteristics Symbol Unit Quantities and declared values Standard
CharacteristicsThermal conductivity SymbolT Unit[°C] Quantities and declared values10 Quantities and declared values50 Quantities and declared values100 Quantities and declared values150 Quantities and declared values200 Quantities and declared values300 Quantities and declared values400 StandardEN 12667
SymbolλN,R Unit[W/(m•K)] Quantities and declared values0.031 Quantities and declared values0.036 Quantities and declared values0.041 Quantities and declared values0.049 Quantities and declared values0.057 Quantities and declared values0.078 Quantities and declared values0.104
CharacteristicsThermal behaviour SymbolT Unit[°C] Quantities and declared valuesExposure to temperature until 400 °C (depends on density) is possible.
From 150 °C on the binder starts to volatilise
StandardAGI Q 132

Sound Absorption Value

Characteristic Symbol Unit Thickness Values Standard
CharacteristicSound absorption value Symbol

αw

Unit- Thickness50 mm Values1.00 Standard-
CharacteristicSound absorption value Symbol

αw

Unit- Thickness60 mm Values1.00 Standard-

Air Flow Resistivity

Characteristic Symbol Unit Quantities and declared values Values Standard
CharacteristicAir flow resistivity Symbolσ Unit[KPa•s/m2] Quantities and declared valuesDensity 56 kg/m3 Values50 StandardDIN EN 29053

Standard Dimensions

Thickness d [mm] Width b [mm]
Thickness d [mm]30 Width b [mm]1200
Thickness d [mm]50 Width b [mm]1200
Thickness d [mm]60 Width b [mm]1200
Notes
* All dimensions require minimum order quantities / other dimensions on request.