Description
ULTIMATE U TECH Wired Mat MT 6.0 is the efficient and sustainable alternative to heavy-dense industry wired mats. Designed for premium-plus thermal insulation at temperatures of up to 620°C, continously and even under tough conditions e.g. mechanical stress like vibrations, U Tech Wired Mat MT 6.0 provides the best combination between thermal efficiency. flexibility and light weight.
U TECH Wired Mat MT 6.0 is produced in AS Quality (CL- ≤ 10 ppm) for usage when in contact with austenitic steel structures. On request with stainless steel wire (X) or yellow glass veil facing (V1) and reinforced aluminium facing (Alu1).
U TECH Wired Mat MT 6.0 is produced in AS Quality (CL- ≤ 10 ppm) for usage when in contact with austenitic steel structures. On request with stainless steel wire (X) or yellow glass veil facing (V1) and reinforced aluminium facing (Alu1).
Key Benefits
- Energy efficiency
- High service temperatures
- Sound insulation
- Fast installation
- Fire reaction
- Easy handling
Technical Characteristics
Symbol | Unit | Quantities and declared values | Standard | |
---|---|---|---|---|
Specific thermal capacity | Symbolc | UnitkJ/(kg·K) | Quantities and declared values1.03 | StandardISO 10456 |
Reaction to fire | Symbol- | Unit- | Quantities and declared valuesNon combustible; Euroclass A1 Fire Spread Index = 0; Smoke Development Index < 20 | StandardEN 13501-1 ASTM E84 |
Water behaviour | SymbolWS | Unitkg/m² | Quantities and declared values No short term water absorption by partial immersion (WS1 ≤ 1 kg/m2) | StandardEN ISO 29767 |
Chemical behaviour | Symbol- | Unit- | Quantities and declared valuesAS-quality (Leachable Chloride ≤10ppm) Leachable chloride content less than 10 ppm (CL10) Do not contribute to corrosion of stainless steel | StandardAGI Q 132 EN 13468 ASTM C795/871 |
Application field | Quantities and declared valuesProduct for use in technical applications, such as big diameter pipes, tanks and vessels, exhaust ducts and stacks or other equipments, with need for: thermal and/or acoustic insulation with high performances especially for improved energy efficient constructions | StandardEN 14303 | ||
Material | Quantities and declared valuesULTIMATE mineral wool, faced with a metallic wire mesh and stainless steel steeching wire With quality marks EUCEB and RAL by the Gütegemeinschaft Mineralwolle e. V., unrisky regarding health according to German decree on dangerous substances, decree on prohibition of chemicals and to regulation EC No 1272/2008 Note Q | StandardCINI 2.2.02 | ||
Facing | Quantities and declared valuesOn request: Reinforced aluminium facing (Alu1) Yellow glass veil facing (V1) | Standard- | ||
Miscellaneous | Quantities and declared valuesInsulating material identification number: 10.01.03.50.07 Designation code : MW-EN-14303-T2-ST(+)620-WS1-CL10 | StandardAGI Q 132 EN 14303 | ||
Quality management | Quantities and declared valuesCE-marked according to EN 14303 Quality control according to VDI 2055 ISOVER is certified according to EN ISO 9001 and EN ISO 14001 | StandardEN 14303 VDI 2055 EN ISO 9001 EN ISO 14001 |
Thermal Conductivity
Characteristic | Symbol | Unit | Quantities and declared values | Standard | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CharacteristicThermal conductivity | SymbolT | Unit[°C] | Quantities and declared values10 | Quantities and declared values_50 | Quantities and declared values__100 | Quantities and declared values___150 | Quantities and declared values____200 | Quantities and declared values_____300 | Quantities and declared values______400 | Quantities and declared values_______500 | Quantities and declared values________600 | StandardEN 12667 EN ISO 13787 |
Symbolλ | Unit[W/(m•K)] | Quantities and declared values0.031 | Quantities and declared values_0.035 | Quantities and declared values__0.040 | Quantities and declared values___0.047 | Quantities and declared values____0.054 | Quantities and declared values_____0.072 | Quantities and declared values______0.096 | Quantities and declared values_______0.120 | Quantities and declared values________0.162 | ||
CharacteristicThermal behaviour | SymbolT | Unit[°C] | Quantities and declared valuesMaximum service temperature 620 (under 500 Pa) Maximum service temperature 700 |
StandardEN 14706 C447/C411 |
Acoustic Parameters
Characteristic | Symbol | Unit | Quantities and declared values | Thickness [mm] | Standard | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
CharacteristicAirflow resistivity* | SymbolAFR (σ) | UnitkPa·s/m2 | Quantities and declared values> 50 | Thickness [mm]> 50 | StandardEN ISO 9053-1 | ||||||
CharacteristicSound absorption* | Symbolαp | UnitHz | Quantities and declared valuesαw | Quantities and declared values125 | Quantities and declared values250 | Quantities and declared values500 | Quantities and declared values1,000 | Quantities and declared values2,000 | Quantities and declared values4,000 | Thickness [mm]- | StandardEN ISO 11654 EN ISO 354 |
Unit- | Quantities and declared values1.00 | Quantities and declared values0.44 | Quantities and declared values1.11 | Quantities and declared values1.01 | Quantities and declared values1.05 | Quantities and declared values1.09 | Thickness [mm]50 | ||||
Unit- |