Description
TECH Roll 2.0 is the highly-flexible and ultra-lightweigth glass mineral wool solution for thermal and acoustic insulation of various industry insulation equipment such as tanks and vessels, exhaust ducts and stacks.
TECH Roll 2.0 can be used for service temperatures up to 200°C. On request with reinforced aluminium facing (Alu2) for service temperatures up to 250°C.
TECH Roll 2.0 can be used for service temperatures up to 200°C. On request with reinforced aluminium facing (Alu2) for service temperatures up to 250°C.
Key Benefits
- Fast installation
- Sound absorption
- On demand
- Fire reaction
- Improved logistics
- Lightweight
Technical Characteristics
Symbol | Unit | Quantities and declared values | Standard | |
---|---|---|---|---|
Specific thermal capacity | Symbolc | UnitkJ/(kg·K) | Quantities and declared values1.03 | StandardISO 10456 |
Reaction to fire | Symbol- | Unit- | Quantities and declared valuesNon combustible; Euroclass A1 Euroclass A2-s1,d0 for TECH Roll 2.0 Alu2 | StandardEN 13501-1 |
Water behaviour | SymbolWS | Unitkg/m² | Quantities and declared values No short term water absorption by partial immersion (WS1 ≤ 1 kg/m2) | StandardEN ISO 29767 |
Chemical behaviour | Symbol- | Unit- | Quantities and declared valuesDo not contribute to corrosion of stainless steel | StandardASTM C795/871 |
Application field | Quantities and declared valuesProduct for use in technical applications, such as tanks and vessels, exhaust ducts and stacks, with need for: thermal and/or acoustic insulation performances especially at ambient to medium temperatures | StandardEN 14303 | ||
Material | Quantities and declared valuesUltra-light and flexible glass mineral wool roll for industry applications. With quality marks EUCEB and RAL by the Gütegemeinschaft Mineralwolle e. V., unrisky regarding health according to German decree on dangerous substances, decree on prohibition of chemicals and to regulation EC No 1272/2008 Note Q | StandardCINI 2.1.02 | ||
Facing | Quantities and declared valuesOn request: Reinforced aluminium facing (Alu2) | Standard- | ||
Miscellaneous | Quantities and declared valuesDesignation code: MW-EN 14303-T2-ST(+/250)200-WS1 | StandardEN 14303 | ||
Quality management | Quantities and declared valuesCE-marked according to EN 14303 ISOVER is certified according to EN ISO 9001 and EN ISO 14001 | StandardEN 14303 EN ISO 9001 EN ISO 14001 | ||
Delivery form | Quantities and declared valuesPlease contact your local ISOVER dealer All dimensions require minimum order quantities | Standard- |
Thermal Conductivity
Characteristic | Symbol | Unit | Quantities and declared values | Standard | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CharacteristicThermal conductivity | SymbolT | Unit[°C] | Quantities and declared values50 | Quantities and declared values_100 | Quantities and declared values__150 | Quantities and declared values___200 | Quantities and declared values____- | StandardEN 12667 EN ISO 13787 |
||||
Symbolλ | Unit[W/(m•K)] | Quantities and declared values0.042 | Quantities and declared values_0.053 | Quantities and declared values__0.067 | Quantities and declared values___0.083 | |||||||
CharacteristicThermal behaviour | SymbolT | Unit[°C] | Quantities and declared valuesMaximum service temperature 200 (under 250 Pa) Maximum service temperature 250 (under 250 Pa) for Alu2 |
StandardEN 14706 |